Facilities Information
Room / Area
Door
Room
Test Bench
 
Room 1
72" x 108"
22' X 15'6" X 120"H
18' X 36"
Room 2
35" X 83 ½"
11'7" X 15'10" X 97"H
15' X 36"
Room 3
47" X 84"
11'7" X 15'10" X 97"H
15' X 36"
Copper Mesh
34" X 84"
13' X 16'6" X 89"H
12'5" X 36"
 
Conducted Area
Ground Plane:    10'1" X 9'2"
8'4" X 32"
Test Area:    10'1" X 16'5"
Part 68 Area
Ground Plane:    10'1" X 16'1"
16' X 30"
Test Area:    10'1" X 16'1"
Site
67" X 91
13'1" X 13'1" X 98 ½"H
Turntable: 48" Round
Facility Power
DC
0 to 600 volts
60Hz
115, 220, 440, 480 & 600 volts
50Hz
230 & 395
400Hz
115 & 220
Basic Test Capabilities
 
Conducted Emissions Power and I/O Ports DC to 1 GHz Current or Voltage
Conducted Emissions RF Ports DC to 110 GHz  

Conducted AF/RF
Susceptibility
/Immunity

Power and I/O Ports DC to 1 GHz

300 mA +150 dBuV(30 V)+

Conducted RF
Susceptibility
/Immunity
RF Ports DC to 40 GHz  

Conducted Transient Susceptibility
/Immunity

All Ports Multiple Waveforms 6 kV / 4 kA +
Radiated Emissions Magnetic Field DC to 30 MHz  
Radiated Emissions Electric Field 10 KHz to 110 GHz  
Radiated Susceptibility /Immunity Magnetic Field DC to 30 MHz 1600 A/M +
Radiated Susceptibility/Immunity Electric Field 10 kHz to 40 GHz 200 V/M +
ESD Air /Contact 0 to 25 kV  
 