Lab Tour  


Capabilities

EMC New Hampshire << Back to Main Capabilities Page


NH Facilities Information   (All Dimensions in Feet)
Room / Area
Door
Room
Test Bench
 
Room 1
6' X 4'
32' X 16' X 12'H
15' X 3'
(outside dimensions including support chamber)
Room 2
6' X 4'
20' X 12' X 10'H
15' X 3'
(outside dimensions including support chamber)
 
Conducted Area 1
Ground Plane:    10' X 8'
N/A
Test Area:   15' X 12'
Conducted Area 2
Ground Plane:    10' X 8'
N/A
Test Area:    28' X 11'
Site
10' X 6'
12' X 13' X 12'H
Turntable: 4' Round
Facility Power
DC
0 to 250 volts
60Hz
115, 220, 440 volts
50Hz
230 & 395
400Hz
115 & 220
NH Basic Test Capabilities
 
Conducted Emissions Power and I/O Ports DC to 1 GHz Current or Voltage
Conducted Emissions RF Ports DC to 40 GHz  

Conducted AF/RF
Susceptibility
/Immunity

Power and I/O Ports DC to 1 GHz

300 mA +150 dBuV(30 V)+

Conducted RF
Susceptibility
/Immunity
RF Ports DC to 40 GHz  

Conducted Transient Susceptibility
/Immunity

All Ports Multiple Waveforms 6 kV / 4 kA +
Radiated Emissions Magnetic Field DC to 30 MHz  
Radiated Emissions Electric Field 10 KHz to 40 GHz  
Radiated Susceptibility /Immunity Magnetic Field DC to 30 MHz 1600 A/M +
Radiated Susceptibility/Immunity Electric Field 10 kHz to 40 GHz 200 V/M +
ESD Air /Contact 0 to 25 kV  
 